Understanding HSA’s Medical Device Registration and Vigilant System
Update On: 24/01/2024
Regulatory Authority: Medical Device Branch of the Health Sciences Authority (HSA)
The Medical Device Branch of Singapore’s Health Sciences Authority (HSA) is in charge of overseeing medical device regulation. The Health Product Act was approved in 2007 by the HSA, giving them the authority to impose mandatory registration requirements, control supply distribution, manufacture, import, and advertising of all health goods.
Medical Device Definition: They are defined as health products which have a physical and mechanical effect when used on human bodies and are used to: diagnose, treat a medical condition, e.g. X-Ray Machine; Measures or monitors the function of the body e.g. Pulse oximeter;
Products which are used to maintain or support well-being, such as body toning equipment, magnetic accessories and massagers, are not medical devices and hence are not regulated by HAS.
Link for Regulatory Authority: https://www.hsa.gov.sg/
Local Regulation: Health Products Act 2007 and Health Products (Medical Devices) Regulations 2010
Medical Device Classification: A, B, C, D
Listing or Registration: Requirements:
For systems, product families or other multi-component devices, determine most favourable grouping strategy according to HSA Guidance GN-12.
* Full Evaluation Route refers to the evaluation process for a medical device that has not received any prior approval from any regulatory agencies. Abridged Evaluation Route refers to a medical device that has received approval from reference regulatory agencies, such as TGA, HC, MHLW, FDA, or EC Certificates. The Immediate/Expedited Evaluation Route allows medical devices to be evaluated if they have received at least one approval, been marketed for at least three years, have no global safety issues, and have no prior rejections. The Priority Review Scheme offers faster registration and market entry for devices in five healthcare areas.
Document Requirements for registration:
The information required in submissions depends on device class and selected evaluation route.
For the most part, documentation from an EU technical file can be used to satisfy many supporting documentation requirements. One must also prepare a Declaration of Conformity to the Essential Principles. Once approved, product is listed in the Singapore Medical Device Register (SMDR) database.
Registration timeline: 1-10 Months
Registration Fee: 25,00$ – 5.700,00$
Class | Application fee | Immediate route fee | Expedited route fee | Abridged route fee | Full route fee | Full route (Priority Review Scheme Route 1) | Full route (Priority Review Scheme Route 2) | Annual retention fee for SMDR listina |
B | $530 | $950 | N/A | $1,910 | $3,710 | $4,220 | $5,460 | $37 |
C | $530 | $3,180 | $3,180 | $3,710 | $6,050 | $6,800 | $8,800 | $64 |
D | $530 | N/A | $5,730 | $6,050 | $11,800 | N/A | N/A | $128 |
D with a registrable drug | $530 | N/A | N/A | $10,400 | $75,400 | N/A | N/A | $128 |
License Validity: Unrestricted Validity but fee must be paid annually
License Renewal: The license will be automatically renewed for another year after the annual renewal fee is paid
Turnaround Time (In working days):
Registration route | Class B | Class C | Class D | Class D with a registrable drug |
Immediate route | Immediate upon submission | Immediate upon submission | N/A | N/A |
Expedited route | N/A | 120 | 180 | N/A |
Abridged route | 100 | 160 | 220 | 220 |
Full route | 160 | 220 | 310 | 310 |
Full route (Priority Review Scheme Route 1) | 120 | 165 | 235 | N/A |
Full route (Priority Review Scheme Route 2) | 120 | 165 | 235 | N/A |
Language Requirements: Documentation and labelling must be provided in English.
Adverse events reporting of medical devices
Any adverse event (AE), which meets the three basic reporting criteria listed below, is considered as a reportable adverse event:
The initial report of an adverse event should contain as much detail as possible and should not be delayed for the sake of gathering more information. If more than one dealer is involved in a reportable AE, each one must submit their own report.
It is mandatory for medical device companies, including product registrants, manufacturers, importers and suppliers, to report any AEs related to the medical devices they deal in.
The following medical device-associated AEs must be reported to us:
Adverse Events | Report Within |
Serious threat to public health | 48 Hrs |
Death | 10 days |
Serious deterioration in state of health | 10 days |
Possible death or serious injury if the adverse event were to recur | 30 days |
Dealers of medical devices are to follow up with a final report within 30 days of the initial report, detailing the investigation into the adverse event. Follow-up reports may be requested as and when necessary.
Submit the Mandatory Medical Device Adverse Event Reporting Form for Medical Device Dealers through e-mail.
What is FSCA?
A FSCA is any action taken to reduce a risk of death or serious deterioration in the state of health associated with the use of a medical device. It is required when it becomes necessary for the medical device product owner to take action to eliminate, or reduce the risk of, the identified hazards.
A FSCA includes:
You need to report a FSCA if the affected device meets any of the following criteria:
Who to report?
The reporting person should be the dealer that manufactured, imported, supplied or the product registrant for the affected devices. In cases where more than one dealer is involved, they may be required to make individual reports.
Reporting procedure
Who should make this communication:
When to make this communication: Before placing a medical device into the market.
How OMC Medical can assist you with the process:
Why Choose Us
Contact us for free consultation: info@omcmedical.co.uk
Our team will be happy to respond your queries. Contact us directly with your questions or for scheduling FREE consultation and we’ll be in touch as soon as possible.
Our team will be happy to respond your queries. Contact us directly with your questions or for scheduling FREE consultation and we’ll be in touch as soon as possible.
Our team will be happy to respond your queries. Contact us directly with your questions or for scheduling FREE consultation and we’ll be in touch as soon as possible.
To launch a medical device in a country, medical devices must comply with the local country’s regulatory requirements. Let us be your trusted partner in bringing your medical devices to the Global market. Contact us today to learn more about how we can assist you in every step of the way.